FEATURES

  • A choice of 24, 28, or 40 pin count devices can be inserted without bending or otherwise damaging the legs, since no force is required to either insert or remove the component from the socket.
  • A metal cam provides strong, smooth action as it moves to a positive stop, compressing the double-sided contacts, ensuring a gas-tight seal.
  • Test point openings provided to reach all pins.

GENERAL SPECIFICATIONS

  • Plastic Body black UL 94 V-0 Glass-filled 4/6 Nylon
  • Contacts BeCu 172, Spring-tempered
  • Contact Plating “-10” 200µ [5.08µ] min. matte Sn per ASTM B545-97(2004)e1 over 50µ [1.27µ] min. Ni per SAE-AMS-QQ-N-290; “-10TL” 200µ [5.08µ] min. 90/10 Sn/Pb per MIL-T-10727 over 50µ [1.27µ] min. Ni per SAE-AMS-QQ-N-290; “-11” 10µ [0.25µ] min. Au per MIL-G-45204 over 50µ [1.27µ] min. Ni per SAE-AMS-QQ-N-290 – Consult factory for availability
  • Cam lightweight, strong, and rigid Cast Zinc alloy
  • Operating Temperature -67°F to 221°F [-55°C to 105°C] Sn & Sn/Pb plating; -67°F to 257°F [-55°C to 125°C] Au plating
  • Contact Current Rating 2 amps
  • Contact Resistance 10 mOhms maximum
  • Breakdown Voltage 1000VAC minimum
  • Average Retention Force (when closed) 110g/Pb, based on 0.010 [0.25] dia. Test Pb
  • Socket accepts 0.008-0.014 [0.20-0.36] thick Leads, 0.075-0.200 [1.91-5.08] long

MOUNTING CONSIDERATIONS

  • Suggested PCB Hole size 0.035 ±0.002 [0.89 ±0.05] diameter
NOTICE   ORDERING INFORMATION

RoHS-compliantALL DIMENSIONS IN INCHES [MILLIMETERS]

CONSULT FACTORY FOR OTHER SIZES & CONFIGURATIONS

ALL TOLERANCES ±0.005 [±0.13] UNLESS OTHERWISE SPECIFIED

PRINTOUTS OF THIS DOCUMENT MAY BE OUT-OF-DATE AND SHOULD BE CONSIDERED UNCONTROLLED

 

 

 

 

 

 

 

Series 516 Standard and ZIF Socket also available. Consult Data Sheet 10017.

Reference-Only Drawing for Series 526 LO-PRO<sup>®</sup>file Zero-Insertion-Force (ZIF) Socket
# Positions
Dim. “A”
Dim. “B”
24
1.450 [36.83]
1.100 [27.94]
28
1.650 [41.90]
1.300 [33.02]
40
2.250 [57.15]
1.900 [48.26]

 