CUSTOMIZATION: IN ADDITION TO THE STANDARD PRODUCTS SHOWN ON THIS PAGE, ARIES SPECIALIZES IN CUSTOM DESIGN AND PRODUCTION. SPECIAL MATERIALS, PLATINGS, SIZES, AND CONFIGURATIONS CAN BE FURNISHED, DEPENDING ON QUANTITY. NOTE: ARIES RESERVES THE RIGHT TO CHANGE PRODUCT SPECIFICATIONS WITHOUT NOTICE.
Series 181 thru 183 90° Pin-Staked Flex Jumper
FEATURES
- 90° Pin-Staked Flex Jumpers combine thin, flexible, solid Cu Conductors embedded between layers of tough, flexible, flame-retardant insulation.
- Consult factory for cable lengths under 2.000 [50.80]
- See Data Sheet 11005 for Flat Pin-Staked Flex Jumpers
- For RoHS applications for Pb-Free Soldering use HT Cable.
GENERAL SPECIFICATIONS
- STANDARD CABLE INSULATION: white UL VW-1, Style 2643 Flame-retardant Polyester (Mylar) adhesive
- HIGH-TEMP FLAME-RETARDANT CABLE INSULATION: Polyimide (Kapton) with Acrylic adhesive
- CABLE CONDUCTORS: solid Cu with a cross-sectional area equivalent to that of 26-gauge AWG
- FEMALE HOUSING: black UL 94V-0 glass-filled Stanyl® 4/6 Nylon
- "CRIMP-ON" PINS: spring-tempered Cu 510
- PIN PLATING: “T” 100µ [2.54µ] min. matte Sn per ASTM B545-97(2004)e1 over 50µ min. Ni per ASTM AMS-QQ-N-290; “TL” 100µ [2.54µ] min. 93/7 Sn/Pb per SAE AMS-P-81728 over 50µ [1.27µ] min. Ni per SAE AMS-QQ-N-290B
- CABLE CURRENT RATING: 3 amps
- CABLE VOLTAGE RATING: 300V
- CABLE DIELECTRIC STRENGTH: 2500V/mil, min. (standard) 4000V/mil, min. (high-temp)
- CABLE INSULATION RESISTANCE: 1000 mΩ min. (standard) 100,000 mΩ (high-temp)
- CONDUCTOR/CONTACT RESISTANCE (avg.): 20 mΩ initial (max. 20 mΩ increase) based on a 2" cable at 20°C
- OPERATING TEMPERATURE: 67 to 257°F [-55 to 105°C]
- FEMALE HOUSING: accepts leads 0.024-0.030 [0.61-0.76] square, 0.150 [3.81] long min.
MOUNTING CONSIDERATIONS
- SUGGESTED PCB HOLE SIZE: 0.032 +0.002 [0.81 +0.05] dia.
| NOTICE | ORDERING INFORMATION | |
ALL DIMENSIONS IN INCHES [MILLIMETERS] CONSULT FACTORY FOR OTHER SIZES & CONFIGURATIONS A” # CONDUCTORS x 0.100 [2.54] KAPTON® IS A REGISTERED TRADEMARK OF DuPONT ALL TOLERANCES ±0.005 [±0.13] UNLESS OTHERWISE SPECIFIED
|
ARIES RESERVES THE RIGHT TO SHIP WITH OR WITHOUT POLARIZATION STRIPE UNLESS OTHERWISE SPECIFIED BY CUSTOMER. ![]() |
PRINTOUTS OF THIS DOCUMENT MAY BE OUT-OF-DATE AND SHOULD BE CONSIDERED UNCONTROLLED
![]() |
Download Data
Sheet 11019, Rev K |